Selection of Generating Sets according to Given Output Continuous Duty Range (KVA):  Click here   Italiano   English
The Company
Presentation
Where
The products
Generating Sets
Control Boards
Cabs/Canopies
Containers
Fuel Tanks
The Services
Our Services
Contact us
Our Addresses
 

SIGEM GENERATING SETS, ASSEMBLED WITH
WATER COOLED DIESEL ENGINE
1500 RPM   400 V   50 Hz

(1) Output in continuous duty with variable load, with no time limit running, and with average load permitted not more than 75%. Overload of 10% is permitted, in intermittent duty, for 1hour each 12 hours of operation. (PRIME POWER)(PRP).

(2) Output in stand-by duty with a variable load and with average load permitted not more than 85%. No overload is permited. Running in case of public mains failure with a maximum time limit of 300 hours per year. (LIMITED-TIME RUNNING POWER ) ( LTP). Powers refer to ISO 8528-1 specification (power factor 0.8) and to the following site conditions  (as to ISO 3046 specification) Barometrical pressure 100 kPA - Temperature 25° C - Relative Humidity 30%.
(3) Diesel engine four-stroke, direct injection.
(4) L = Vertical in line configuration, V = "V" configuration
(5) NA = Naturally aspirated, TA = Turbocharged, TCA = Turbocharged and aftercooled
(6) Governor: M = Mechanical - E = Electronic
(7) Dimensions referred to regular immovable base types; for special ones equipped with accessories, dimensions and weight will increase or decrease.

All data subject to change without notice.
 
Generating set  SIGEM
type
Output
continuous duty
KVA  (1)  KW
Output
stand-by duty
kVA (2)  KW
Diesel engine type
(3)
Number of cylinders
(4)
Total displacement
liters
Air induction system
(5)
Governor
(6)
Generating set overall dimensions
length x width x height
mm  (7)
Weight
kg
 
VP 85.5 85  68 94   75 TD520GE 4 L 4,76 TC M 2300x950x1400

1550

VP 100.5 100  80 110   88 TAD520GE 4 L 4,76 TCA M 2300x950x1400

1800

VP 130.5 130  104 142   113 TD720GE 6 L 7,15 TC M 2600x1000x1450

1950

 
VP 150.5 150  120 165   132 TAD720GE 6 L 7,15 TCA M 2600x1000x1450

2150

 
VP 185.5 185  148 200   160 TAD721GE 6 L 7,15 TCA E 2600x1000x1500

2300

 
VP 200.5 200  160 225   180 TAD722GE 6 L 7,15 TCA E 2600x1000x1500

2550

 
VP 250.5 250  200 275   220 TAD740GE 6 L 7,28 TCA E 2600x1000x1500

2700

 
VP 300.5 300  240 330   264 TAD1032GE 6 L 9,60 TCA E 2900x1200x1800

2950

 
VP 325.5 325  260 360   288 TAD1240GE 6 L 12,13 TCA E 2900x1200x1800

3100

 
VP 375.5 375  300 410   328 TAD1241GE 6 L 12,13 TCA E 2900x1200x1800

3400

 
VP 400.5 400  320 450   360 TAD1242GE 6 L 12,13 TCA E 2900x1200x1800

3500

 
VP 470.5 470  376 515   412 TAD1630GE 6 L 16,12 TCA E 3100x1350x1950

3700

 
VP 510.5 510  408 560   448 TAD1631GE 6 L 16,12 TCA E 3100x1350x1950

3950

 
 
 
MTU
CUMMINS
MAN
VOLVO PENTA
IVECO Motors
SAME Diesel
PERKINS
MANUAL
SWITCH BOARDS
AUTOMATIC AT30

AUTOMATIC AT100

BURIED TANKS
EXTERNAL TANKS
      8 ÷     30
    31 ÷     60
    61 ÷   100
  101 ÷   190
  191 ÷   300
  301 ÷   400
  401 ÷   600
  601 ÷   900
  901 ÷ 1750